57
3-23 Code 93
Read:
Format
Data digits (variable)
2 check digits (optional)
Check digit verification: The check digit is made as the sum module 47 of the numerical values of all data
digits.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
3-15 Code 39 (Code 32, Trioptic Code 39)
.
Code ID setting: Refer to Code ID setting of
3-10 UPC-A
.
Insertion group selection: Refer to Insertion group selection of
3-10 UPC-A
.