70
3-29 Telepen
Read:
Format
Start character (_)
Data digits (variable)
Check digit
End character (z)
Check digit verification: The check digit verification is optional.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
3-15 Code 39 (Code 32, Trioptic Code 39)
.
Code ID setting: Refer to Code ID setting of
3-10 UPC-A
.
Insertion group selection: Refer to Insertion group selection of
3-10 UPC-A
.
Encode character set type: Two options. Same Telepen symbol, with different option, is associated
with different data output.
Alphanumeric- Supports both letters and numbers within the data source.
Numeric- Supports only numbers within the data source and ignores all letters.