76
PG DRIVES TECHNOLOGY
11
SP1B - P
ROGRAMMING
SK73750/7
On a single-ended type system, No means that if the reverse switch input is connected
to 0V then direction will be reverse, Yes is opposite to this.
4.8 PwrDn Timer ?
A length of time can be set, such that if the controller accepts no valid input for that
period of time, it will power down safely. The time can be set from 0 to 20 minutes. If
the value is set to 0, no power down will occur.
4.9 Read Timer ?
Later versions of Egis have a timer which records how long the controller has been
driven.
This function is not present on Solo controllers.
4.10 Read System Log ?
Later versions of Egis have a diagnostic log facility which stores the number of
occurrences of the last eight detected system problems. This prompt allows you to
view the contents. Refer to Chapter 2 to interpret the contents of the log.
This function is not present on Solo controllers.