81
SP1B
SK73750/7
PG DRIVES TECHNOLOGY
16
batteries. The value corresponds to the total resistance in both the positive and negative
paths.
You can set this between 10mΩ and 250mΩ in steps of 5mΩ.
5.18 TruCharge Cal. ?
This allows further fine calibration of the TruCharge battery gauge. This is normally set
at the factory and should not need adjustment. Please contact PGDT if you are
considering altering this factor.
5.19 Max. Charge Amps ?
If the Egis controller is being used with a scooter on-board battery charger and a
PGDT TruCharge display, then an indication of the battery charge status can be given
on the TruCharge display.
This parameter should be set to a value corresponding to the charger’s current output
when the batteries are fully discharged. The value is displayed in “units” of 0.1A and
is adjustable from 0A to 12A in steps of 0.1A.
This function is not present on Solo controllers.
5.20 Min. Charge Amps ?
If the Egis controller is being used with a scooter on-board battery charger and a
PGDT TruCharge display, then an indication of the battery charge status can be given
on the TruCharge display.
This parameter should be set to a value corresponding to the charger’s current output
when the batteries are fully charged. The value is displayed in “units” of 0.1A and is
adjustable from 0A to 12A in steps of 0.1A.
This function is not present on Solo controllers.
5.21 Erase System Log?
This function clears the controller’s diagnostic log.
This function is only present on later Egis controllers.
5.22 Clear Timer?
This function resets the controller’s timer.
This function is only present on later Egis controllers.
5.23 Back to root ?
This takes you back to the ROOT
menu.