MITEL AG4100 ANALOG GATEWAY - QUICK INSTALLATION GUIDE
04/2024 5
Install the Analog Gateway in a well-ventilated location, away from high humidity and
elevated temperatures:
o Humidity inferior to 85% and non-condensing,
o Storage temperature: -20 °C to +80 °C (-4 Deg F to 170 Deg. F),
o Operating temperature: 0 °C to +45 °C (32 Deg. F to 110 Deg. F).
1.4 WIRING GUIDELINES
These guidelines apply to any type of cables used with the Analog Gateway.
Use cables that are long enough, with no side pressure or pressure on connectors.
Keep cables away from:
o Sources of electrical noise such as radios, radio transmitters, and broadband amplifiers,
o Power lines,
o Fluorescent lighting fixtures,
o Liquids or moisture,
o Heat sources.
Make sure the mains power supply provides 100-240 VAC 50/60Hz.
Make sure the Analog Gateway power supply is connected to a dedicated mains AC circuit
with a grounded connection.
For the Mitel AG4124 hardware maintenance, unplug the RJ11 (Front) and RJ21 (Rear)
cables of the Mitel AG4124 at first. Unplug the Mitel AG4124 power supply from the mains
power next.
For the Mitel AG4172 hardware maintenance, unplug the RJ21 (Rear) cables of the
Mitel AG4172 at first. Unplug the Mitel AG4172 power supply from the mains power next.
For additional information, refer to the documents Ethernet Twisted Pair Cabling Plant, Power
and Grounding Guidelines and the local wiring code for guidelines on routing data cables.