EasyManua.ls Logo

Mitsubishi Electric FX3U-1PG - Page 47

Mitsubishi Electric FX3U-1PG
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Before Starting Positioning Operation
6.6 Operation Speed Change Function
41
FX3U-1PG User's Manual
1
Introduction
2
Specification
3
System
Configuration
4
Installation
5
Wiring
6
Before Starting
Positioning
Operation
7
Buffer Memory
8
Manual Control
9
Positioning
Control
10
Program
Example
3. Update time for the operation speed change value
After the operation speed change value is updated, the time required until the operation speed changes is as
follows.
During operation at 1 kHz or higher: Within 3 ms
During operation at less than 1 kHz: Within 3 pulses
Cautions when the operation speed change function is used
In the following conditions, writing a value to the operation speed change value does not validate the
operation speed change. No error will occur either.
- During deceleration by the STOP command (STOP, forward limit, reverse limit)
- During deceleration and stopping of the positioning operation
- Operation that the operation speed change function cannot be used
- During use of the approximate S-shaped acceleration/deceleration function
- In JOG operation inching movement
- During remaining distance operation waiting (remaining distance operation is cancelled)
- After interrupt input detection of the interrupt stop operation
When the value set for the speed change value is larger than the maximum speed, the operation will be
executed in the maximum speed. When the value set for the speed change value is at the bias speed or
smaller, the operation will be executed at the bias speed. However, if the bias speed is 0, the operation is
executed at 1 Hz.
When the value set for the speed change value is at the creep speed or smaller, the operation will be
executed at the creep speed. (In DOG type mechanical zero return operation)
If the travel time is shorter than the required acceleration/deceleration time, the operation speed set by the
speed change value cannot be reached.
Time
Travel time
Time required for acceleration/deceleration
Speed
Actual operation
speed
Operation speed
before change
Operation speed
after change