EasyManua.ls Logo

Mitsubishi Electric FX3U-1PG - 7.5 Monitor Data

Mitsubishi Electric FX3U-1PG
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Buffer Memory
7.4 Control Data
71
FX3U-1PG User's Manual
1
Introduction
2
Specification
3
System
Configuration
4
Installation
5
Wiring
6
Before Starting
Positioning
Operation
7
Buffer Memory
8
Manual Control
9
Positioning
Control
10
Program
Example
7.4 Control Data
Set the data for positioning control.
Point
The control data becomes valid when an operation starts. Therefore, set before the start-up of the operation.
When the setting is changed during the operation or during the remaining distance operation waiting, the
change is not reflected to the current operation but from the next operation.
However, setting can be changed during operation for the operation speed I, the target address change
value, the operation speed change value, the operation command (b1 to b3), and the operation command II
of the variable speed operation.
7.4.1 [BFM#16] Starting delay time
Set the start delay time of the FX3U-1PG.
After the operation command, the operation starts when the time set for the startup delay time has elapsed
after the normal startup time
*1
.
*1. 1 ms or less for the motor system unit, and 2 ms or less for the machine system unit.
Point
The positioning operations that correspond to the starting delay time is as follows.
1-speed positioning operation
Interrupt 1-speed positioning operation
2-speed positioning operation
External command positioning operation
Variable speed operation
Interrupt stop operation
Interrupt 2-speed positioning operation
BFM No.
Description R/W Default
High order
16bit
Low order
16bit
- #16 Setting range: 0 to 1,000 ms R/W K0

Table of Contents

Other manuals for Mitsubishi Electric FX3U-1PG

Related product manuals