B-13
FX Series PLC User's Manual - Data Communication Edition
N:N Network
3 System Configuration and Equipment Selection
3.2 Applicable FX PLC and Communication Equipment
A
Common Items
B
N:N Network
C
Parallel Link
D
Computer Link
E
Inverter
Communication
F
Non-Protocol
Communication
(RS/RS2 Instruction)
G
Non-Protocol
Communication
(FX
2N
-232IF)
H
Programming
Communication
I
Remote
Maintenance
Apx.A
Discontinued
models
3.2 Applicable FX PLC and Communication Equipment
Select a (optional) communication equipment combination, and put a check mark in the "Check" column.
During selection, pay attention to the following:
-
In the table below, only the external dimensions are different between the units shown in "FX
2NC
-485ADP/
FX0N-485ADP". Select either one.
- In the table below, only the cable is different between the units shown in "FX
3G-485-BD/FX3G-485-BD-
RJ". Select either one.
- N:N Network is not provided for the FX
1, FX2(FX), FX2C, FX0 and FX0S PLCs.
FX Series Communication equipment (option)
Total extension
distance
Check
FX
0N
500 m
(1640' 5")
FX
1S
50 m
(164' 0")
500 m
(1640' 5")
FX
1N
50 m
(164' 0")
500 m
(1640' 5")
FX
2N
50 m
(164' 0")
500 m
(1640' 5")
FX2NC-485ADP
(European terminal block)
FX0N-485ADP
(Terminal block)
FX
1N
-485-BD
(European terminal block)
FX1N-CNV-BD
+
FX2NC-485ADP
(European terminal block)
FX0N-485ADP
(Terminal block)
FX1N-CNV-BD
+
FX
1N
-485-BD
(European terminal block)
FX1N-CNV-BD
+
FX2NC-485ADP
(European terminal block)
FX0N-485ADP
(Terminal block)
FX1N-CNV-BD
+
FX
2N
-485-BD
FX
2N
-CNV-BD
+
FX
2NC
-485ADP
(European terminal block)
FX
0N
-485ADP
(Terminal block)
FX
2N
-CNV-BD
+