REPLACEMENT OF THE MELSECNET/10 (PLC TO PLC NETWORK)
4 - 15
4
(1) Parameter of control station
: Compatible, : Partial change required, ×: Incompatible
4.5 Parameter Comparisons
Parameter
name
Description
Compat-
ibility
Precautions for replacementA/AnS/QnA/QnAS series
MELSECNET/10 module
Q series
MELSECNET/H module
(MELSECNET/10 mode)
Network
parameter
Network type Network type
Starting I/O No. Starting I/O No.
Network No. Network No.
Network No.240 to No.255 cannot be
set.
Alternate them with unused network
Nos.
Total number of (slave)
stations
Total number of (slave)
stations
- Group No.
Set the group No. in GX Works2 or
GX Developer network parameters.
- Mode
Set the mode in GX Works2 or GX
Developer network parameters.
Network range
assignment
(common
parameter)
Monitoring
time
Network range
assignment
(common
parameter)
Monitoring
time
LB/LW setting LB/LW setting
LX/LY setting LX/LY setting
I/O master
station
specification
I/O master
station
specification
Reserved
station
designation
Reserved
station
designation
Supplemental
settings
Supplemental
settings
Station inherent parameter Station inherent parameter
Refresh parameters Refresh parameters
Inter-link data transfer Inter-link data transfer
Routing parameters Routing parameters
Valid module during other
station access
Valid module during other
station access