5) Performance comparison of AJ71BR11/A1SJ71BR11/AJ71QBR11/A1SJ71QBR11 and
QJ71BR11
: Compatible, : Partial change required, × : Incompatible
*1 Remote master station remote sub-master station, remote I/O station: 8192 points
Remote sub-master station, remote I/O station remote master station: 8192 points
*2 The remote master station includes the multiplexed remote master station and multiplexed remote sub-master station.
*3 For the multiplexed remote I/O network, one station in 32 stations of the remote I/O station is used for the multiplexed
remote sub-master station.
Item
Specifications
Compatibility Precautions for replacement
AJ71BR11
A1SJ71BR11
AJ71QBR11
A1SJ71QBR11
QJ71BR11
Maximum number
of link points per
network
LX/LY 8192 points
LB 8192 points
16384 points
*1
LW 8192 points
16384 points
*1
Maximum number of link
points per station
<Remote master
station remote I/O
station>
{(LY + LB) 8 + (2 ×
LW)} 1600 bytes
<Remote I/O station
remote master
station>
{(LY + LB) 8 + (2 ×
LW)} 1600 bytes
<Remote master station remote I/O station>
*2
{(LY + LB) 8 + (2 × LW)} 1600 bytes
<Remote I/O station remote master station>
*2
{(LY + LB) 8 + (2 × LW)} 1600 bytes
<Multiplexed remote master station multiplexed
remote sub-master station>
{(LY + LB) 8 + (2 × LW)} 2000 bytes
Communication speed 10Mbps
Communication method Token bus method
Synchronous type Frame synchronization method
Encoding method Manchester code
Transmission method Single bus
Transmission format HDLC standards (frame format)
Maximum number of
networks
255 (Total number of
PLC to PLC networks
and remote I/O
networks)
239 (Total number of PLC to PLC networks and
remote I/O networks)
Network No.240 to No.250 cannot
be set. Alternate them with
unused network No.
Number of stations connected
in one network
33 stations (Remote master station: 1, remote I/O station: 32)
*3
Applicable cable 3C-2V, 5C-2V, 5C-FB
Overall distance
3C-2V: 300m
5C-2V, 5C-FB: 500m
Distance between stations
3C-2V: 300m
5C-2V, 5C-FB: 500m
Error control system
CRC(X
16
+ X
12
+ X
5
+ 1) and retry by a time over
RAS function
Diagnostic function for checking local link lines
Abnormal detection using link special relays and link special registers
Network monitoring and various diagnostic functions
Transient transmission
Monitor, program up/download with
peripheral device
Dedicated link instruction
Available for Intelligent function module
(only AJ71QBR11/A1SJ71QBR11)
1:1 communication
(Monitor, program up/
download)
Dedicated link instruction
For comparison of dedicated link
instruction, refer to Section 5.1.7.
Number of occupied I/O
points
32 points per slot (I/O assignment: special 32
points)
32 points per slot (I/O
assignment: intelli. 32 points)