FX2NC Series Programmable Controllers Diagnostics 7.
7-9
D8060
D8061
D8062
D8063
D8064
D8065
D8066
D8067
D8068
D8069
Reports location of I/O
configuration error (see Figure 7.3)
Error code for PC hardware error
Error code number for programmer
communications fault
Error code for parallel link fault
Parameter error code
Systax error code
Program (circuit) error code
Program execution error code
Latched step
number of execution error
Step number of errors associated
with error flags M8065-M8067
1 0 7 0
A) No.10 to 370
B) 1=X
0=Y
Figure 7.3:
I/O configuration error, A) number, B) type.