FX2NC Series Programmable Controllers Introduction 1.
1-14
1.5.1 Summary
Connection of FX
2NC
series extension blocks only
The FX
2NC
series input extension blocks and FX
2NC
series output extension blocks can be
directly connected to the FX
2NC
series main unit. These input/output extension blocks can be
connected in the desired order. After connection, octal numbers will be assigned to the input/
output points of the extension blocks. These octal numbers are regarded as the input/output
numbers. The smallest number will be assigned to the input/output point next to the main unit,
and then sequentially increased for the subsequent input/output points.
Before connection, calculate the number of connectable input/output points by referring to Sec.
1.5.3, or quickly obtain this number using the table shown in Sec. 1.5.5.
FX
2NC
-32MT-D/UL
X: 16 points
Y: 16 points
16EX
16 points
X020
X037
16EX
16 points
16EYT
16 points
16EX
16 points
16EYT
16 points
16EYT
16 points
16EX
16 points
16EYT
16 points
-
X000-X017
X040
X057
-
X060
X077
-
X100
X117
-
Y000-Y017
Y020
Y037
-
Y040
Y057
-
Y060
Y077
-
Y100
Y117
-