256
(2) Replacement procedure of the Q6BAT battery for the High Performance model
QCPU, Process CPU, Redundant CPU and Universal model QCPU
Backup time
3 minutes
Open the CPU module bottom cover.
Close the CPU module bottom cover.
Failure of CPU module battery
Bit 0 is on.
Bit 0 is OFF.
OFF
ON
Install the CPU module into the
base unit.
Remove the old battery from its
holder.
Remove the CPU module from the
base unit.
Insert a new battery into the holder
in the correct direction. Connect the
lead to the connector.
Completed
Monitor
SM51 to verify
on/off.
Monitor
SD52 to check if bit 0 is
ON.
Battery Q6BAT
Connector CPU
module side
Connector
battery side
CPU module
Backup the program and the
data.
Replacing battery
Turn off the programmable controller
power supply.
Turn on the programmable controller
power supply.