EasyManua.ls Logo

Mitsubishi Electric Q173CPU - 5.3 Operating System Software Installation Procedure

Mitsubishi Electric Q173CPU
472 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 - 17
5 MOTION DEDICATED PLC INSTRUCTION
5.4 Current Value Change Instruction from The PLC CPU to The Motion CPU:
S(P).CHGA (PLC instruction:
S(P).CHGA
)
Refer to Section "1.3.4" for the applicable version of the Motion CPU and the software.
• Current value change instruction from the PLC CPU to the Motion CPU (S(P).CHGA)
Usable devices
Internal devices
(System, User)
MELSECNET/10
direct J
\
Setting data
(Note)
Bit Word
File
register
Bit
digit
specified
Indirectly
specified
device
Bit Word
Special
function
module
U
\G
Index
register
Z
Constant
K, H
Other
(n1)
(S1)
(S2)
(D1)
(D2)
: Usable : Usable partly
(Note) : Setting data except (S1) : Index qualification possible
(S1)SP.CHGA
SP.CHGA
Start request
S.CHGA
(S2) (D1) (D2)
(n1)
(S1)
S.CHGA
(S2) (D1)
(D2)
(n1)
[Instruction] [
Condition]
Start request
[Setting data]
Setting data Description Data type
(n1)
(First I/O No. of the target CPU)/16
Value to specify actually is the following.
(Note-1)
CPU No.2 : 3E1H, CPU No.3 : 3E2H, CPU No.4 : 3E3H
16-bit
binary
Axis No. ("Jn")
(Note-2)
to execute the current value change.
Q173CPU(N) : J1 to J32/Q172CPU(N) : J1 to J8
Synchronous encoder axis No. ("En") to execute the current value change.
Q173CPU(N) : E1 to E12/Q172CPU(N) : E1 to E8
(S1)
Cam axis No. ("Cn") to execute the within-one-revolution current value change.
Q173CPU(N) : C1 to C32/Q172CPU(N) : C1 to C8
Character
sequence
(S2) Setting of the current value to change.
32-bit
binary
(D1)
Complete devices
(D1+0) : Device which make turn on for one scan at start accept completion of
instruction.
(D1+1) : Device which make turn on for one scan at start accept abnormal
completion of instruction.
("D1+0" also turns on at the abnormal completion.)
Bit
(D2) Device to store the complete status.
16-bit
binary
(Note-1) : Motion CPU cannot used CPU No.1 in the Multiple CPU configuration.
(Note-2) : "n" shows the numerical value which correspond to axis No..
Q173CPU(N) : Axis No.1 to No.32 (n=1 to 32) / Q172CPU(N) : Axis No.1 to No.8 (n=1 to 8)