EasyManua.ls Logo

Mitsubishi Electric Q173CPU - 10 Motion Devices; Motion Registers (#0 to #8191)

Mitsubishi Electric Q173CPU
472 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 - 1
10 MOTION DEVICES
10
10. MOTION DEVICES
The motion registers (#0 to #8191) and coasting timer (FT) are available as Motion
CPU-dedicated devices.
They can be used in operation control (F/FS) programs or transition (G) programs.
10.1 Motion Registers (#0 to #8191)
Motion device Item Specifications
Number of points 8192 points (#0 to #8191)
Data size 16-bit/point
Latch
Only a user device is latched.
(All points are cleared by latch clear operation.)
Usable tasks Normal, event and NMI
Motion register (#)
Access Read and write enabled in whole range
(1) Motion register list
• Common to all operating system
Device No. Application Signal direction
#0
to
User devices
(8000 points)
• Cleared by latch clear.
#8000
to
Motion SFC
dedicated devices
(64 points)
• Cleared at power on or reset only.
(Note-1)
• Cleared by the Motion SFC error history request flag
on (keep at power on or reset).
(Note-2)
#8064
to
#8191
Servo monitor
devices
(128 points)
• Cleared at power on or reset only.
(Note-1) : SW6RN-SV13Q /SV22Q (Ver. 00M or before)
(Note-2) : SW6RN-SV13Q
/SV22Q (Ver. 00N or later)
POINT
The motion registers (#) cannot be set as indirectly specified devices of mechanical
system programs.

Table of Contents