2 - 3 2 - 3
MELSEC-Q
2 SYSTEM CONFIGURATIONS
(2) Support of the multiple CPU system
When using the QD62 (E/D) in a multiple CPU system, refer to the following
manual first.
• QCPU User's Manual (Multiple CPU System)
If the QD62 (E/D) is used in a multiple CPU system, there are no restrictions
depending on the module version.
Write intelligent function module parameters to the control CPU of the QD62
(E/D).
(3) Supported software packages
Relation between the system containing the QD62 (E/D) and software package is
shown in the following table.
GX Developer is necessary when using the QD62 (E/D).
Software Version
GX Developer GX Configurator-CT
Single CPU system
Version 7 or
later
Q00J/Q00/Q01CPU
Multiple CPU system
Version 8 or
later
Version 1.10L or later
(cannot be used with the
SW0D5C-QCTU-E 50F
or earlier versions)
Single CPU system
Version 4 or
later
SW0D5C-QCTU-E 00A
or later Q02/Q02H/Q06H/Q12H/
Q25HCPU
Multiple CPU system
Version 6 or
later
SW0D5C-QCTU-E 50F
or later
Single CPU system
Q02PH/Q06PHCPU
Multiple CPU system
Version 8.68W
or later
Single CPU system
Q12PH/Q25PHCPU
Multiple CPU system
Version 7.10L
or later
Version 1.13P or later
(cannot be used with the
SW0D5C-QCTU-E 50F
or earlier versions)
Q12PRH/Q25PRHCPU Redundant CPU system
Version 8.45X
or later
Version 1.16S or later
Single CPU system
Q00UJCPU/Q00UCPU/
Q01UCPU
Multiple CPU system
Version 8.76E
or later
Single CPU system
Q02U/Q03UD/
Q04UDH/Q06UDHCPU
Multiple CPU system
Version 8.48A
or later
Single CPU system
Q10UDHCPU/
Q20UDHCPU
Multiple CPU system
Version 8.76E
or later
Single CPU system
Q13UDH/Q26UDHCPU
Multiple CPU system
Version 8.62Q
or later
Single CPU system
Q03UDE/Q04UDEH/
Q06UDEH/Q13UDEH/
Q26UDEHCPU
Multiple CPU system
Version 8.68W
or later
Single CPU system
Q10UDEHCPU/
Q20UDEHCPU
Multiple CPU system
Version 8.76E
or later
Version 1.25AB or later
If installed in a MELSECNET/H remote I/O station
Version 6 or
later
SW0D5C-QCTU-E 50F
or later
(4) Connector
For the QD62(E/D), the connector is sold separately.
See Section 4.3 and make separate arrangements for the connector.