Communication operation and setting
Real-time monitor
Refer to page 244 for details of the monitor description.
*1 Input terminal monitor details
*2 Output terminal monitor details
*3 Details of option input terminal monitor 1 (input terminal status of FR-A7AX)-all terminals are off when an option is not fitted
*4 Details of option input terminal monitor 2 (input terminal status of FR-A7AX)-all terminals are off when an option is not fitted
*5 Details of option input terminal monitor (output terminal status of FR-A7AY/A7AR)-all terminals are off when an option is not fitted
b15 b0
⎯⎯⎯⎯CS RES
STOP
MRS JOG RH RM RL RT AU STR STF
b15 b0
⎯⎯⎯⎯⎯⎯⎯⎯⎯
ABC2 ABC1
FU OL IPF SU RUN
b15 b0
X15 X14 X13 X12 X11 X10 X9 X8 X7 X6 X5 X4 X3 X2 X1 X0
b15 b0
⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯DY
b15 b0
⎯⎯⎯⎯⎯⎯RA3RA2RA1Y6Y5Y4Y3Y2Y1Y0
*6 The setting depends on capacities. (01800 or less / 02160 or more)
Register Definition
Increments
40201 Output frequency 0.01Hz
40202 Output current
0.01A/
0.1A
*6
40203 Output voltage 0.1V
40205 Frequency setting 0.01Hz
40206 Running speed 1r/min
40207 Motor torque 0.1%
40208
Converter output
voltage
0.1V
40209
Regenerative brake
duty
0.1%
40210
Electronic thermal
relay function load
factor
0.1%
40211
Output current peak
value
0.01A/
0.1A
*6
40212
Converter output
voltage peak value
0.1V
40213 Input power
0.01kW/
0.1kW
*6
40214 Output power
0.01kW/
0.1kW
*6
40215
Input terminal
status
*1
⎯
40216
Output terminal
status
*2
⎯
40217 Load meter 0.1%
40218
Motor excitation
current
0.01A/
0.1A
*6
40219 Position pulse ⎯
40220
Cumulative
energization time
1h
40222 Orientation status ⎯
40223
Actual operation
time
1h
40224 Motor load factor 0.1%
40225 Cumulative power 1kWh
Register Definition
Increments
40226 Torque command 0.1%
40227
Torque current
command
0.1%
40228 Motor output
0.01/
0.1kW
*6
40229 Feedback pulse ⎯
40250 Power saving effect Variable
40251
Cumulative saving
power
Variable
40252 PID set point 0.1%
40253
PID measured
value
0.1%
40254 PID deviation value 0.1%
40258
Option input
terminal status1
*3
⎯
40259
Option input
terminal status2
*4
⎯
40260
Option output
terminal status
*5
⎯
Register Definition
Increments