EasyManua.ls Logo

Mitsubishi FR-A740-00023-EC - Page 353

Mitsubishi FR-A740-00023-EC
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
343
Communication operation and setting
4
PARAMETERS
Parameter
Parameters
Register Parameter Name Read/Write Remarks
0 to 999
41000 to
41999
Refer to the parameter list (page 65) for
the parameter names.
Read/write
The parameter number + 41000 is the
register number.
C2(902) 41902
Terminal 2 frequency setting bias
(frequency)
Read/write
C3(902)
42092
Terminal 2 frequency setting bias
(analog value)
Read/write
The analog value (%) set to C3 (902) is
read.
43902
Terminal 2 frequency setting bias
(terminal analog value)
Read
The analog value (%) of the voltage (current)
applied to the terminal 2 is read.
125(903) 41903
Terminal 2 frequency setting gain
(frequency)
Read/write
C4(903)
42093
Terminal 2 frequency setting gain
(analog value)
Read/write
The analog value (%) set to C4 (903) is
read.
43903
Terminal 2 frequency setting gain
(terminal analog value)
Read
The analog value (%) of the voltage
(current) applied to the terminal 2 is read.
C5(904) 41904
Terminal 4 frequency setting bias
(frequency)
Read/write
C6(904)
42094
Terminal 4 frequency setting bias
(analog value)
Read/write
The analog value (%) set to C6 (904) is
read.
43904
Terminal 4 frequency setting bias
(terminal analog value)
Read
The analog value (%) of the current (voltage)
applied to the terminal 4 is read.
126(905) 41905
Terminal 4 frequency setting gain
(frequency)
Read/write
C7(905)
42095
Terminal 4 frequency setting gain
(analog value)
Read/write
The analog value (%) set to C7 (905) is
read.
43905
Terminal 4 frequency setting gain
(terminal analog value)
Read
The analog value (%) of the current (voltage)
applied to the terminal 4 is read.
C8(930) 41930 Current output bias signal Read/write
C9(930) 42120
Current output bias current Read/write
C10(931) 41931
Current output gain signal Read/write
C11(931) 42121 Current output gain current Read/write
C12(917) 41917
Terminal 1 bias frequency (speed) Read/write
C13(917)
42107
Terminal 1 bias (speed) Read/write Analog value (%) set in C13 (917) is read.
43917
Terminal 1 bias (speed)
(terminal analog value)
Read
Analog value (%) of the voltage applied to
terminal 1 is read.
C14(918) 41918
Terminal 1 gain frequency (speed) Read/write
C15(918)
42108 Terminal 1 gain (speed) Read/write Analog value (%) set in C15 (918) is read.
43918
Terminal 1 gain (speed)
(terminal analog value)
Read
Analog value (%) of the voltage applied to
terminal 1 is read.
C16(919) 41919
Terminal 1 bias command (torque/
magnetic flux)
Read/write
C17(919)
42109
Terminal 1 bias (torque/magnetic flux) Read/write Analog value (%) set in C17 (919) is read.
43919
Terminal 1 bias (torque/magnetic flux)
(terminal analog value)
Read
Analog value (%) of the voltage applied to
terminal 1 is read.
C18(920) 41920
Terminal 1 gain command (torque/
magnetic flux)
Read/write
C19(920)
42110
Terminal 1 gain (torque/magnetic flux) Read/write Analog value (%) set in C19 (920) is read.
43920
Terminal 1 gain (torque/magnetic flux)
(terminal analog value)
Read
Analog value (%) of the voltage applied to
terminal 1 is read.
C38(932) 41932
Terminal 4 bias command (torque/
magnetic flux)
Read/write
C39(932)
42122 Terminal 4 bias (torque/magnetic flux) Read/write Analog value (%) set in C39 (932) is read.
43932
Terminal 4 bias (torque/magnetic flux)
(terminal analog value)
Read
Analog value (%) of the current (voltage)
applied to terminal 4 is read.
C40(933) 41933
Terminal 4 gain command (torque/
magnetic flux)
Read/write
C41(933)
42123
Terminal 4 gain (torque/magnetic flux) Read/write Analog value (%) set in C41 (933) is read.
43933
Terminal 4 gain (torque/magnetic flux)
(terminal analog value)
Read
Analog value (%) of the current (voltage)
applied to terminal 4 is read.

Table of Contents