69
Parameter List
Parameter List
4
PARAMETERS
⎯
168
Parameter for manufacturer setting. Do not set.
⎯
169
Cumulative monitor
clear
170
Watt-hour meter clear 0, 10, 9999
1 9999 244
171
Operation hour meter clear 0, 9999
1 9999 244
User group
172
User group registered display/batch
clear
9999, (0 to 16)
1 0 299
173
User group registration 0 to 999, 9999
1 9999 299
174
User group clear 0 to 999, 9999
1 9999 299
input terminal function assignment
178 STF terminal function selection
0 to 20, 22 to 28, 37, 42
to 44, 50, 60, 62, 64 to
71, 74, 9999
1 60 222
179
STR terminal function selection
0 to 20, 22 to 28
, 37
, 42 to
44, 50, 61, 62, 64 to 71,
74,
9999
1 61 222
180
RL terminal function selection
0 to 20, 22 to 28, 37, 42
to 44, 50, 62, 64 to 71,
74, 9999
1 0 222
181 RM terminal function selection 1 1 222
182 RH terminal function selection 1 2 222
183 RT terminal function selection 1 3 222
184 AU terminal function selection
0 to 20, 22 to 28, 37, 42
to 44, 50, 62 to 71, 74,
9999
1 4 222
185 JOG terminal function selection
0 to 20, 22 to 28, 37, 42
to 44, 50, 62, 64 to 71,
74, 9999
1 5 222
186
CS terminal function selection
1 6 222
187
MRS terminal function selection
1 24 222
188
STOP terminal function selection
1 25 222
189
RES terminal function selection
1 62 222
Output terminal function assignment
190
RUN terminal function selection
0 to 8, 10 to 20, 25 to 28,
30 to 36, 39, 41 to 47, 64,
70, 84, 85, 90 to 99,
100 to 108, 110 to 116,
120, 125 to 128, 130 to
136, 139, 141 to 147,
164, 170, 184, 185, 190
to 199, 9999
1 0 230
191
SU terminal function selection
1 1 230
192 IPF terminal function selection 1 2 230
193 OL terminal function selection 1 3 230
194
FU terminal function selection
1 4 230
195
ABC1 terminal function selection
0 to 8, 10 to 20, 25 to 28,
30 to 36, 39, 41 to 47, 64,
70, 84, 85, 90, 91, 94 to
99, 100 to 108, 110 to
116, 120, 125 to 128, 130
to 136, 139, 141 to 147,
164, 170, 184, 185, 190,
191, 194 to 199, 9999
1 99 230
196
ABC2 terminal function selection
1 9999 230
Multi-speed
setting
232 to 239
Multi-speed setting(8 speed to 15
speed)
0 to 400Hz, 9999
0.01Hz 9999 160
⎯ 240
Soft-PWM operation selection 0, 1
1 1 278
⎯ 241
Analog input display unit switchover 0, 1
1 0 282
⎯
242
Terminal 1 added compensation
amount (terminal 2)
0 to 100%
0.1% 100% 278
⎯ 243
Terminal 1 added compensation
amount (terminal 4)
0 to 100%
0.1% 75% 278
⎯
244
Cooling fan operation selection 0, 1
1 1 373
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial Value
Refer
to
Page
Customer
Setting