71
Parameter List
Parameter List
4
PARAMETERS
Brake sequence function
278 Brake opening frequency 0 to 30Hz 0.01Hz 3Hz 208
279 Brake opening current 0 to 220% 0.1% 130% 208
280
Brake opening current detection time 0 to 2s
0.1s 0.3s 208
281
Brake operation time at start 0 to 5s
0.1s 0.3s 208
282
Brake operation frequency 0 to 30Hz
0.01Hz 6Hz 208
283
Brake operation time at stop 0 to 5s
0.1s 0.3s 208
284
Deceleration detection function
selection
0, 1 1 0 208
285
Overspeed detection frequency
(Excessive speed deviation detection frequency)
0 to 30Hz, 9999
0.01Hz 9999
111,
208
Droop control
286
Droop gain 0 to 100%
0.1% 0% 363
287
Droop filter time constant 0 to 1s
0.01s 0.3s 363
288 Droop function activation selection 0, 1, 2, 10, 11 1 0 363
⎯
291
Pulse train input selection 0, 1
1 0 365
⎯
292 Automatic acceleration/deceleration 0, 1, 3, 5 to 8, 11 1 0
157,
173,
208
⎯
293
Acceleration/deceleration separate
selection
0 to 2
1 0 173
⎯
294 UV avoidance voltage gain 0 to 200% 0.1% 100% 258
⎯ 299
Rotation direction detection selection
at restarting
0, 1, 9999
1 0 254
RS-485 communication
331
RS-485 communication station number 0 to 31(0 to 247)
1 0 320
332
RS-485 communication speed
3, 6, 12, 24,
48, 96, 192, 384
1 96 320
333 RS-485 communication stop bit length 0, 1, 10, 11 1 1 320
334
RS-485 communication parity check
selection
0, 1, 2 1 2 320
335
RS-485 communication retry count 0 to 10, 9999
1 1 320
336
RS-485 communication check time
interval
0 to 999.8s, 9999
0.1s 0s 320
337
RS-485 communication waiting time
setting
0 to 150ms, 9999
1 9999 320
338
Communication operation command
source
0, 1
1 0 310
339
Communication speed command
source
0, 1, 2 1 0 310
340
Communication startup mode
selection
0, 1, 2, 10, 12 1 0 309
341
RS-485 communication CR/LF
selection
0, 1, 2
1 1 320
342
Communication EEPROM write
selection
0, 1
1 0 321
343
Communication error count
⎯
1 0 333
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial Value
Refer
to
Page
Customer
Setting