55
DRIVE THE MOTOR
3
Start/stop from the operation panel (PU operation)
REMARKS
Operation cannot be performed at the set frequency ... Why?
Did you carry out step 4 within 5s after step 3? (Did you press within 5s after turning ?)
The frequency does not change by turning ... Why?
Check to see if the operation mode selected is the External operation mode. (Press to change to the PU operation
mode.)
Operation does not change to the PU operation mode ... Why?
Check that "0" (initial value) is set in Pr. 79 Operation mode selection?
Check that the start command is not ON.
Change acceleration deceleration time
Pr. 7 (Refer to page 46)
Change deceleration time
Pr. 8 (Refer to page 46)
For example, operation not exceeding 60Hz
Set "60Hz" in Pr. 1. (Refer to page 45)
When you always operate in the PU operation mode at powering ON, set Pr.79 Operation mode selection = "1" to choose PU
operation mode always.
Press to show the set frequency.
can also be used like a potentiometer to perform operation. (Refer to page 56)
Use Pr. 295 Magnitude of frequency change setting to change the frequency setting increments of .