Parameter list
3.6 Parameter list
3.6.1 List of parameters classified by the purpose
Set parameters according to the operating conditions. The following list indicates purpose of use and corresponding
parameters.
Purpose of Use Parameter Number
Adjust the output torque
(current) of the motor
Manual torque boost Pr. 0, Pr. 46
General-purpose magnetic flux vector control Pr. 80
Slip compensation Pr. 245 to Pr. 247
Stall prevention operation Pr. 22, Pr. 23, Pr. 48, Pr. 66, Pr. 156, Pr. 157
Limit the output frequency
Maximum/minimum frequency Pr. 1, Pr. 2, Pr. 18
Avoid mechanical resonance points
(frequency jump)
Pr. 31 to Pr. 36
Set V/F pattern
Base frequency, voltage Pr. 3, Pr. 19, Pr. 47
V/F pattern matching applications Pr. 14
Frequency setting with
terminals (contact input)
Multi-speed setting operation Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239
Jog operation Pr. 15, Pr. 16
Remote setting function Pr. 59
Acceleration/deceleration
time/pattern adjustment
Acceleration/deceleration time setting Pr. 7, Pr. 8, Pr. 20, Pr. 44, Pr. 45
Starting frequency Pr. 13, Pr. 571
Acceleration/deceleration pattern Pr. 29
Regeneration avoidance function Pr. 665, Pr. 882, Pr. 883, Pr. 885, Pr. 886
Selection and protection
of a motor
Motor protection from overheat
(electronic thermal relay function)
Pr. 9, Pr. 51
Use the constant torque motor
(applied motor)
Pr. 71, Pr. 450
Offline auto tuning Pr. 71, Pr. 82 to Pr. 84, Pr. 90, Pr. 96
Motor brake and stop
operation
DC injection brake Pr. 10 to Pr. 12
Selection of regeneration unit Pr. 30, Pr. 70
Selection of motor stopping method and start
signal
Pr. 250
Decelerate the motor to a stop at
instantaneous power failure
Pr. 261
Function assignment of
external terminal and
control
Function assignment of input terminal Pr. 178 to Pr. 182
Start signal selection Pr. 250
Logic selection of output stop signal (MRS) Pr. 17
Terminal assignment of output terminal Pr. 190, Pr. 192, Pr. 197
Detection of output frequency (SU, FU signal) Pr. 41 to Pr. 43
Detection of output current (Y12 signal)
Detection of zero current (Y13 signal)
Pr. 150 to Pr. 153, Pr. 166, Pr. 167
Remote output function
(REM signal)
Pr. 495, Pr. 496
Monitor display and
monitor output signal
Speed display and speed setting Pr. 37
Change of DU/PU monitor descriptions
Cumulative monitor clear
Pr. 52, Pr. 170, Pr. 171, Pr. 563, Pr. 564, Pr. 891
Change of the monitor output from terminal
FM
Pr. 54 to Pr. 56
Selection of the decimal digits of the monitor Pr. 268
Adjustment of terminal FM output (calibration) C0 (Pr. 900)
Detection of output
frequency and current
Detection of output frequency (SU, FU signal) Pr. 41 to Pr. 43
Detection of output current (Y12 signal)
Detection of zero current (Y13 signal)
Pr. 150 to Pr. 153, Pr. 166, Pr. 167