60
Start/stop from the operation panel (PU operation)
3.4.5 Setting the frequency by analog input (current input)
POINT
Use operation panel ( ) to give a start command.
Frequency command is given by current input (across terminals 4 and 5.)
Set "4" in any of Pr. 178 to Pr. 182 (input terminal function selection) and turn the AU signal ON.
Pr. 178 to Pr. 182 are extended parameters. Set "0" in Pr. 160. (Refer to page 74)
Pr. 79 Operation mode selection must be set to "4" (External/PU combined operation mode 2).
[Connection diagram]
[AU signal assignment]
Assign the AU signal in any of Pr. 178 to Pr. 182.
(example) Assign the AU signal to the terminal RH.
Set "4" (AU signal) in Pr. 182 RH terminal function selection.
Operation Display
1.
Screen at powering ON
The monitor display appears.
2. Press to choose the PU operation mode.
PU indication is lit.
3. Press to choose the parameter setting
mode.
PRM indication is lit.
(The parameter number read previously
appears.)
4. Turn until " " (Pr. 182) appears.
5. Press to show the currently set value " "
(initial value).
6. Turn to change the set value to " ".
7. Press to set.
Flicker...parameter setting complete!!
5(-)
4(+)
SD
Inverter
Operation
panel
AU signal
Current signal
source
(4 to 20mADC)
AU signal
(terminal RH)