8 9. DETAILS OF EACH FUNCTION
I
OPERATION MODE SELECTION, PARAMETER WRITE PROHIBITION ‘AND
REVERSING PREVENTION
I
Parameter WRITE prohibition
q
I-?
WRITE parameter can be prohibited. .
Setting
0
. Description
WRITE parameter is possible. (Initial setting)
I
9, 1,
1
I
WRITE parameter is impossible. (Note)
Note: Function (parameter) No. 77 and 79 can still be written.
Reversing prevention
q q
Reversing of motor operation can be prevented.
Setting Description
0
Motor operation can be reversed. (initial setting)
n ,,
1 Motor operation cannot be reversed. (Note)
Note: Reversing is impossible in PU operation mode as well as in external
signal operation mode.
Operation mode selection [91 @l
Operation mode can be fixed to either PU operation or external signal
operation , or both.
.
Setting
Description
0
Switching between “,PU operation and external signal
operation is possible. (Initial setting)
1, ,t
1
Only PU operation is possible.
‘99
2 Only
external signal operation is possible.
Note: Function (parameter) No. 79 can be changed even in external
‘.
I
signal operation mode.
_ -.
.
..-
.