Setting
Correction
” 0 ” Speed (frequency) is not corrected (initial setting) .
9. ,,
1 Speed (frequency) is corrected.
Note: The signal should be input through terminal ” 1 K ” or ” 1 E ” .
PWM MODE
PWM mode
q q
By changing carrier frequency (hertz) ,
motor sound and vibration can be reduced.
80Hz per graduation change.
One of 16 carrier frequencies can be selected.
Note: Initial setting is ” 3 ” .
SPEED DISPLAY
Speed display .a 0
Motor speed can be directly displayed in MONITOR mode in terms of rpm or
m/min, instead of inverter output frequency.
Displayed motor speed is that converted from inverter output frequency, and not
always equal to true speed.
Setting ” 0 ” Inverter output frequency (Hz) is displayed (initial setting) .
Setting
”
2 ” - ” 10 ”
(Number of
motor poles
is input.)
Motor speed is displayed ,in rpm. (Note
11
Setting
” 11 ” - ” 9998 ”
Speed of load is displayed. (Note 2 >
Ex.: 1 . Display of ,mot.or speed (r-pm)
When 4 -pole motor is driven by the inverter.
Notes: 1 . Setting should be an even number (motor poles) within the range
0
0
-ml-