terminals  FU  and  SE.  Otherwise,  ” H ”  level  signal  is  output. 
This  signal  can 
be  used  to  control  a  mechanical  brake  or  other  device.  When 
it  is  set,  to  ” 9999 ” , 
the  function  is  changed  and  areference  indicating  that  the 
inverter  is  in 
” PU  operation  ”  mode  is  output  from  termainal  FU. 
Output  frequency  detection  during  reverse  operation  @  •I 
(Terminal  FU) 
For  operation  of  a  hoist  or 
elevator,  for  example,  operation  timing  of  magnetic 
brake  can  be  set  differently  between  forward, 
run  (up)  and  reverse,  run  (down)  . 
Frequency  detection 
q 
•0 
The  initial  setting  is  “ 9999”)  where  output 
frequency  is  detected  at  6 Hz  during  forward 
run  and  reverse  run. 
FREQUENCY  METER  CALIBRATION 
Frequency  meter  calibration  m] 
Frequency  meter 
Frequency  meter  can  be  calibrated,  without 
use  of  calibration  potentiometer,  by  operating 
the  PU. 
(For  method,  refer  to  5.1  .> 
FM  terminal  output  basic  frequency  m 
q 
A  pulse  train  signal  is  output  from 
terminal  FM.  When  a  digital  counter  is 
connected  to  terminal  FM,  frequency  can  be 
monitored  through  the  digital  counter. 
fnverter  output  frequency  at  1440Hz  of 
pulse  train  signal  can  be  set. 
I 
f 
Digital  counter 
I- 
1 
+SD 
Note:  The  initial  setting  is 
that  1 mA  full  scale  is  read  and  pulse  train  signal 
frequency  ._ is 
1440Hz  when  the  output  frequency  is  60Hz. 
. . 