13E-14
(4) Fuel injection rate adjustment resistor correction amount
To limit inconsistency in the injection quantity, the injection quan-
tity is corrected by the fuel injection rate adjustment resistor.
2.4 Fuel injection timing control
(1) Main injection timing
The main injection timing is calculated from the fuel injection
quantity and engine speed.
(2) Pilot injection timing (pilot interval)
The pilot injection timing is calculated from the fuel injection
quantity and engine speed.
2.5 Fuel injection pressure control
The fuel injection pressure is calculated from the fuel injection
quantity and engine speed.
2.6 Warm-up acceleration function
The warm-up acceleration function accelerates engine warm-up by varying the engine’s idling speed in accor-
dance with the engine’s coolant temperature. It can operate either automatically or manually. Selection is made
using the idling speed adjustment potentiometer.