Auto Off Timer
●
The auto off timer begins counting down when the air conditioner starts, and stops the air conditioner when the set time
passed.
●
The time on the auto off timer can be set in a range of 30 minutes to 4 hours, in 30-minute increments.
* By default, the weekly timer is selected as the remoter controller’s timer function.
To use the auto off timer, switch the timer function to the auto off timer using the remote controller’s function selection.
Note 1 : If the auto off timer is selected, it is not possible to use the weekly and simple timers.
Note 2 : Timer operation is not possible when:
A timer is operating, an error has occurred, the air conditioner is operating, the remote controller is diagnosing a
problem, function selection is in progress, timer setting is in progress, or the system is centrally controlled.
(ON/OFF operation is prohibited under the above conditions.)
Selecting the Auto Off Timer
TIMER MODE
OFF
AUTO OFF
TIMER
SIMPLE
TIMER
WEEKLY
TIMER
Steps (1) to (5) are necessary when switching the timer function from simple timer, weekly timer and no timer.
(1) While pressing the
MODE
button, press the
ON/OFF
button for two seconds to activate the remote controller’s
function selection mode.
(2) Press the
MODE
button until
MODE
SELECTION
appears on the screen (at
).
[Display
]
(3) Press the
MENU
button so that “Timer” appears on the screen (at ).
(4) Press the
ON/OFF
button until
AUTO OFF
TIMER
appears on the screen (at ).
[Display
]
(5) While pressing the
MODE
button, press the
ON/OFF
button for two seconds to return to normal mode.
* If you press the
ON/OFF
button before the
MODE
button, the settings you have made will be cancelled.