Connect external load devices
e.g.
contactors, pilot lamps, solenoid (electromagnetic)
valves,
etc.,
0
The load limitation
of
the transistor outputs
is
1A
for
each individual ouiput, but the collective
output toad should not exceed
2A
per
4
points
at
DC
24V.
8
Due to surge current limitations lamp loads should be within 3W.
0
When other load are connected to
a
output termination in addition to lamp load, the totaf collec-
tive
output load should be
as
specified with reference to following table.
to output terminations
of
the base unit and extension unit.
i
\
2w
6W
1w
I
16W
I
I
0
24W
I
0
The external DC power supply should be
DC
24V
+15%/-30%.
0
2A
rated back-up fuses or protectors are recommended per each four outputs
'to
prevent damage
to the circuit boards
of
the PC in the event of
a
short circuit fault in one of the external circuits.
4-4
TRANSISTOR OUTPUT
MODELS
(F2-40/600T-ESS)
SOURCE OUTPUT
TYPE
1
130
I
32 I34 136
1
14301432143414361 15301532153415361
I
1
I
DC24VO 41 43 45 47 441 443
445
447 541 543 545 547
DC24VQ
-
12
-