APPENDICES
Appendix 4 Sample Programs when Using CC-Link
Appendix 4.4 Parameter Settings
App - 18
9
PROCESSING TIME
FOR REDUNDANT
SYSTEMS
APPENDICESINDEX
(3) CC-Link Network Parameter Settings
(a) Example of CC-Link Network Parameter Settings
An example of CC-Link network parameter settings is shown in Diagram App.4.
Refer to (b) for the actual settings.
(b) The content of CC-Link Network Parameter Settings
The content of network parameter settings is shown below.
1) Module Count
Set module count to "1" in network parameter settings.
2) Starting I/O Number
Set the master station's starting I/O number to "40".
3) Type
Confirm that the station type is "Master Station (Duplex function)".
4) Mode
Set CC-Link's mode as "Remote Network - Ver.1 Mode".
5) All Connect Count
Set the total number of systems connected to the CC-Link system, including
reserved stations to "4 (Systems)".
Diagram App.4 CC-Link Network Parameter Setting Screen