5 - 51 
MELSEC-Q
5   DATA USED FOR POSITIONING CONTROL 
 
[Table 1] 
 
Pr.1
setting value 
Value set with peripheral device 
(unit) 
Value set with sequence program
(unit) 
0 : mm 
0 to 214748364.7 (
μ
m) 
0 to 2147483647 (
10
-1
μ
m) 
1 : inch  0 to 21474.83647 (inch) 
0 to 2147483647 (
10
-5
inch) 
2 : degree  0 to 21474.83647 (degree) 
0 to 2147483647 (
10
-5
degree) 
3 : pulse  0 to 2147483647 (pulse)  0 to 2147483647 (pulse) 
 
Deceleration time: Tb=300ms
Creep speed: Vc=1kpulse/s
Actual deceleration time:t = Tb
t
Vz
Vp
Pr.47
Speed limit value: Vp=200kpulse/s
Pr.8
OPR speed:
Vz=10kpulse/s
Pr.46
[Machine OPR operation]
Example of setting for " Pr. 50   Setting for the movement amount after near-point dog ON"
Assuming that the " Pr. 8  Speed limit value" is set to 200 kpulse/s, " Pr. 46  OPR speed" to 10 kpulse/s, 
" Pr. 47  Creep speed" to 1 kpulse/s, and deceleration time to 300 ms, the minimum value of " Pr. 50  Setting for the 
movement amount after near-point dog ON" is calculated as follows:
[Deceleration distance] =
1
2
Vz
1000
t + 0.01    Vz
Movement amount for 
10ms at OPR speed
=
Tb  Vz
Vp
+ 0.01    Vz
Vz
2000
=
300   10   10
200   10
10   10
2000
3 3
3
+ 0.01    10    10
3
= 75 + 100
= 175
Setting for the movement amount after 
near-point dog ON ( Pr. 50 ) should be 
equal to or larger than 175.
 
 
Pr.51
OPR acceleration time selection 
 
Set which of "acceleration time 0 to 3" to use for the acceleration time during OPR. 
 
0 : Use the value set in "
Pr.9
Acceleration time 0". 
1 : Use the value set in "
Pr.25
Acceleration time 1". 
2 : Use the value set in "
Pr.26
Acceleration time 2". 
3 : Use the value set in "
Pr.27
Acceleration time 3". 
 
Pr.52
OPR deceleration time selection 
 
Set which of "deceleration time 0 to 3" to use for the deceleration time during OPR. 
 
0 : Use the value set in "
Pr.10
Deceleration time 0". 
1 : Use the value set in "
Pr.28
Deceleration time 1". 
2 : Use the value set in "
Pr.29
Deceleration time 2". 
3 : Use the value set in "
Pr.30
Deceleration time 3".