EasyManua.ls Logo

Mitsubishi QD75P1N - Page 585

Mitsubishi QD75P1N
858 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 - 87
MELSEC-Q
12 CONTROL SUB FUNCTIONS
(2) When entering teaching data into "
Da.7
Arc address" and then into
"
Da.6
Positioning address/movement amount" (Teaching example for 2-
axis circular interpolation control with sub point designation on axes 1 and 2)
Start
Carry out a machine OPR.
Move the workpiece to the
circular interpolation sub point
using a manual operation. *1
Set Writes the current feed value
to Da.7 Arc address in teaching
data selection.
Set the positioning data No. for
which the teaching will be carried
out.
Using a JOG operation, inching operation, or manual pulse generator.
Set 1 in the buffer memory address [1548].
Set the positioning data No. in buffer memory address [1549].
Confirm completion of the
teaching.
Confirm 0 in buffer memory address [1549].
Teach arc sub point address of
axis 2.
Entering teaching data to buffer memory address [1648] and [1649],
in the same fashion as for axis 1.
Move the workpiece to the
circular interpolation end point
using a manual operation. *2
Using a JOG operation, inching operation, or manual pulse generator.
Set Writes the current feed value
to Da.6 Positioning address/
movement amount by teaching
data selection.
Set 0 in buffer memory address [1548].
Set the positioning data No. for
which the teaching will be carried
out.
Set the positioning data No. in buffer memory address [1549].
Confirm completion of the
teaching.
Confirm 0 in buffer memory address [1549].
Teaching arc sub point address on axis 1
Teaching arc end point address on axis 1
2)
1
)