Setting the upper limit
1 Press and hold the [
SET] key
.
⇨ The sign will blink and can be changed.
Continue to step 3 if not changing the sign.
2 Press the [MODE] key to change the sign.
⇨ Each time the [MODE] key is pressed, it will
switch the sign between "+" and "-".
3 Press the [SET] key.
⇨ The sign is confirmed and the neighboring digit
blinks.
4 Press the [MODE] key to change the number.
⇨ Each time the [MODE] key is pressed, it will
switch values in the order of
"0→1→2...→9→0".
5 Press the [SET] key.
⇨ The number is confirmed and the neighboring
digit blinks. Press the [SET] key again to skip
over the digit.
Repeat steps 1 and 2 above until the numbers for
all digits are confirmed.
⇨ Confirming the last digit will cause [►] to blink.
6 Press the [SET] key.
⇨ The upper limit is set, [◄] blinks, and the lower
limit can be set.
6
Setting the lower limit
1 Set in the same way as the upper limit (step
5
).
2 Press the [SET] key.
⇨ Settings are confirmed.
For 0.001 mm models:
Proceed to step
2
in "3) Switching
resolution".
For 0.01 mm models:
Proceed to step
2
in "4) Setting calculation
function".
Tips
• If the upper limit is set below the lower limit, the error display [Err 90]
appears and the set value is cleared. Clear the error display by
pressing the [SET] key and amend the settings, starting with the upper
limit. (Refer to "12. Error Displays and Countermeasures")
• The tolerance values cannot be set for "normal display" and "enlarged
display" separately.
• The tolerance limit values are automatically converted when the unit
system or resolution is changed. In this case, however, a conversion
error may be produced. It is therefore recommended to check the
tolerance limit values after changing the unit system or resolution.
• Press and hold the [MODE] key to stop or cancel settings midway
through. Note that unconfirmed settings will not be reflected.
• All settings are retained even when the power is turned off. However,
they are cleared when replacing the battery and must be reset.
3) Switching resolution (0.001 mm or 0.00005 in models only)
The resolution setting can be changed for 0.001 mm or 0.00005
in models only.
1
Press and hold the [MODE] key to enter
parameter setting mode.
⇨ Shifts to parameter setting mode.
2
Selecting the parameter item to set
1 Press the [MODE] key until [rES.] is displayed.
2 Press the [SET] key.
⇨ Resolution can be set.
3
Setting the resolution
1 Press the [MODE] key to select the resolution.
⇨ Each time the key is pressed, it will switch
the resolution in the order as follows:
For mm display:
0.001 mm→0.01 mm→0.001 mm
For inch display:
0.00005 in→0.0001 in →0.0005 in
→0.00005 in
2 Press the [SET] key.
⇨ Settings are confirmed; shifts to next
parameter item.
( Proceed to step
2
in "4) Setting
Calculation function".)
4) Setting Calculation function
In addition to normal measurement, this product can also perform calculation measurement, in
which results are displayed by multiplying the spindle movement amount by a calculation
coefficient. The calculation method differs as follows for each measurement system (ABS/INC).
・ Absolute measurement (ABS): Displayed value = (preset value) + (calculation coefficient) x
(spindle movement amount)
・ Incremental measurement (INC): Displayed value = (calculation coefficient) x (spindle
movement amount)
sin
2
θ
2
θ
1 - sin
-
A=R=Ax
ABS INC
sin 60
1 - sin 60
-
=
- 6.4641
=
θ (120°)
R
θ (120°)
R
1
2 -1
-1
2 -2
3 -2
3 -1
Key icon operation
1
Press and hold the [MODE] key to enter parameter setting mode.
⇨ Shifts to parameter setting mode.
2
Selecting the parameter item to set
1 Press the [MODE] key until [CAL.] is displayed.
2 Press the [SET] key.
⇨ Calculation function can be set.
3
Setting the execution (on/off) of the calculation function
1 Press the [MODE] key to select between on/off.
⇨ Each time the [MODE] key is pressed, it will switch
the calculation function between "on" and "oFF".
2 Press the [SET] key.
⇨ Selection is confirmed.
If [on] was selected:
[Ax] will blink and the calculation coefficient can be
set.
If [oFF] was selected:
The display switches to the next parameter item.
(Proceed to step
2
in "5) Executing/
canceling function lock function".)
4
Setting the calculation coefficient
1 Press and hold the [
SET] key
.
⇨ The first digit will blink and can be set.
2 Press the [MODE] key to change the number.
⇨ Each time the [MODE] key is pressed it will
switch values in the order of
"0→1→2...→9→0".
3 Press the [SET] key.
⇨ The number is confirmed and the neighboring
digit blinks. Press the [SET] key again to skip
over the digit.
Repeat steps 2 and 3 above until the numbers for
all digits are confirmed (example: 6.4641).
⇨ Confirming the last digit will cause [Ax] to
blink.
4 Reconfirm the numerical value set and press the
[SET] key.
⇨ Calculation coefficient is confirmed; shifts to
next parameter item.
(Proceed to step
2
in "5) Executing/
canceling function lock function".)
Tips
• The calculation coefficient can be set to a value between 0.0001 and 99.9999.
• Calculation coefficient is not converted even when the unit system or the resolution is switched.
• If the calculation coefficient is set to 0.0000, [Err 00] is displayed.
Clear the error display by pressing and holding the [SET] key and amend the settings with the
correct value. (Refer to "12. Error Displays and Countermeasures")