Operating the unit
52 Operating instructions
5.11 Pausing and finishing use
Switch off the unit during pauses and when finished using it.
Period of idleness lasting more than 2 days
Requirement
GN containers, baking sheets and grates removed from the cooking
zone
No food to be cooked in the cooking zone
1. Use AutoShower to rinse for 1 minute (see Starting AutoShower).
2. Run the unit in the Steaming mode for 7 minutes at 100 °C.
Period of idleness lasting more than 7 days
Requirement
GN containers, baking sheets and grates removed from the cooking
zone
No food to be cooked in the cooking zone
1. Use AutoShower to rinse for 5 minutes (see Starting AutoShower).
2. Run the unit in the Steaming mode for 1 hour at 100 °C.
10015160-0ABBE--