Cleaning and caring for the unit
62 Operating instructions
6.13 Removing and installing the air diverter
CAUTION
Pinch hazard from rotating fan
Prior to working on the unit, ensure that the unit has been
disconnected from the mains.
Do not operate the unit without the air diverter.
Removing the air diverter
Prerequisite
Unit disconnected from power
1. Remove core temperature sensor from holder.
2. Remove right and left support racks.
3. Use tool to remove water supply pipe.
4. Use tool to remove upper fasteners.
5. Use tool to remove lower fasteners.
6. Remove the air diverter from the pins.
Installing the air diverter
1. Place the air diverter on the pins.
2. Use tool to close upper fastener.
3. Use tool to close lower fasteners.
4. Use tool to install water supply pipe.
5. Insert right and left support racks.
6. Insert core temperature sensor into holder.
6.14 Inspecting the unit
6.14.1 Performing a visual inspection
ATTENTION
Risk of physical damage from improper inspection
Inspect in accordance with the inspection intervals.
Have inspections performed by a capable user.
In the event of damage or signs of wear, contact customer
service immediately and stop using the unit.
Prerequisite
Unit disconnected from power
Unit empty and cleaned
Cooking zone door opened completely
Inspect housing, cooking zone door and cooking zone yearly for
deformation and damage.