EasyManua.ls Logo

MONARCH INSTRUMENT PLS - 5.2 BRITE (Brightness); 5.3 SAVE

MONARCH INSTRUMENT PLS
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
5.2 BRITE (Brightness)
Adjust the ash pulse width and consequently the brightness. See Section
6.0. When the display shows:
SEtUP
BRITE
Press the MENU button to enter. Width can be set in degrees or
microseconds.
DEG - Set the ash width in degrees from 0.1° to 10.0°. Use the UP/
DOWN button ▲▼ to change the degrees in 0.1° steps. Note that
the decade being edited can be changed using the LEFT or
RIGHT buttons.
5.6
DEG
Press the MENU button to move to microseconds.
uSEC - Set the ash width in microseconds from 0.5 to 1300 µsec. The
display will default to a conversion of the degrees to microseconds
for the current fl ash rate.
1234
uSEC
To accept this press MENU again. To adjust the ash rate in
microseconds, use the ▲▼ button. Note that the decade being
edited can be changed using the LEFT ◄ or RIGHT ► buttons.
Press MENU to save and return to the main menu.
5.3 SAVE
Saves the current ash rate to a memory location. When the display
shows:
SEtUP
SAVE
Press MENU to select, use the UP/DOWN button ▲▼ to select a

Related product manuals