EasyManua.ls Logo

Money Controls SCH2 - Page 30

Money Controls SCH2
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SCH2 Technical Manual TSP016.doc Issue 3.0 – January 2005
Money Controls 2005. All rights reserved.
Page 30 of 61
Dispense Verification
Request hopper status Ö check event counter
If { event counter not incremented } then
Retry
Dispense hopper coins
While { payout coins remaining > 0 }
Request hopper status
Test hopper Ö check error flags are clear
If { error flags set } then
Resolve from the following error conditions…
<Coin jam> if max. current exceeded
<Hopper empty> if payout timeout
<Opto fraud attempt> if any opto error flag
Optional… Level Auditing
Request hopper dispense count Ö store host copy for subsequent verification
Request payout high / low status Ö is the hopper nearly empty ?
Early Notification of Power Fail
Emergency stop
Request hopper status Ö store unpaid coins for next power-up initialisation
Wait for power to disappear