SECTION Ill
EMERGENCY PROCEDURES
MOONEY
M20J
ANNUNCIATOR PANEL WARNING LIGHTS
WARNING LIGHT FAULT
&
REMEDY
Gear Unsafe
Left or Right Fuel
Low
LDG. GR. in transit or not fully ex-
tended or retracted. Refer to "Failure
of Landing Gear to Extend
Electrical-
lyl',pg. 3-12 or "failure of Landing
Gear to
RetractU,page 3-13.
2
112 to 3 gallons of usable fuel
remain in the respective tanks.
Switch to fuller tank.
VAC (Flashing) Suction is below
4.25
In. Hg
VAC (Steady)
Suction is above
5.5
In. Hg.
--------
I
MOTE
I
Attitude and directional gyros are unreliable when VAC
light
is
illuminated (steady or flashing). Vacuum system should be
checked andlor adjusted as soon as practicable.
Volts (Flashing)
Volts (Steady)
Ram Air
Start Power ON
Low voltage. Refer
toUAlternator Low
Voltage" on page
3-1
2.
Overvoltage or tripped Voltage
Relay. Refer to "Alternator
Failure" on page
3-1
1.
Ram Air light is ON when landing
gear is extended. Close Ram Air
before landing.
Switch or relay has malfunctioned
and starter is energized. Flight
should be terminated as soon as
practicable. Engine damage may
result.