22
To ensure that the stove always has an optimal combustion and to
avoid malfunctions, frequent cleaning operations must be carried
out. The frequency of these operations may vary according to the
time of use of the stove and quality of the pellets.
An overall accurate maintenance check up of the stove must be
carried out annually, and this must be performed by a qualified
technician. The stove must be kept in such a way as to preserve
conditions that ensure safety and efficiency.
WARRANTY CONDITIONS
Warranty certification
Thanking you for choosing our product, Moretti Fire s.r.l. invites you to
consult the user manual and to read the following warranty conditions
The manufacturer provides the customer with a 24 month period
warranty over the product, that starts from the date of purchase. In order
to enable the warranty, the client must send the warranty certificate to
manufacturer headquarters, completely filled in, within 8 days from the
date of purchase and must keep a copy as proof of the purchase. It must
be sent to the following address:
Moretti Fire s.r.l. – C.da Tesino, 50 - 63065 Ripatransone (AP) ITALY
or via e-mail: info@morettidesign.it
A non received or incomplete warranty card voids the warranty.
Warranty conditions
The warranty is limited and only covers manufacturing defects.
Components not covered by warranty:
Glass
Ignition resistance
Firewall
Seals
Majolica
The burner
Paint
The warranty does not cover damage caused by:
No first ignition and testing procedure carried out by a qualified technical
assistance centre (expense on the client’s behalf).
Installation performed by non professional personnel and not in
compliance with standard regulations or used in a different manner than
that it was designed for.
Electrical overloads caused by lightening or non conformed electrical
sockets.
Transport and tampering by unauthorized personnel.
The non application at least once a year of cleaning and routine
maintenance procedures of the product by a qualified authorized service
(expense on the client’s behalf).
The use of cheap/poor quality fuel or any other material that can damage
the product.
Any damage caused by an improper installation and/or disattention of
the user.
The following interventions are not considered under warranty:
Interventions to adjust combustion parameters.
Interventions to repair damaged parts caused by poor maintenance.
EXCLUSION OF LIABILITY
Failure to comply with the operating conditions and decadence of the
warranty will result in the exclusion of the manufacturer from all liability
for any damage to the customer to animals and other people.
MAINTENANCE
Before performing any maintenance procedures on the stove, follow
these precautions:
- Wait until all parts of the stove are cold.
- Wait until the ashes are completely off.
- Make sure that the switch is in the “0“ position.
- Make sure that the power cable has been disconnected from the main
power supply.
PLEASE FOLLOW CAREFULLY THE FOLLOWING CLEANING
INSTRUCTIONS!
MORETTI DESIGN IS NOT RESPONSIBLE FOR DAMAGE TO
PEOPLE, ANIMALS OR THINGS CAUSED BY A NON-COMPLIANCE
OF THE FOLLOWING INDICATIONS.
In addition to the annual maintenance that must be carried out by
authorized personnel, frequent cleaning procedures such as cleaning the
burner, emptying the ash drawer and cleaning the tube bundle should be
carried out.
Cleaning the burner
To be performed before each ignition, It is necessary to check if the
burner is clean, that there are no combustion residuals or if the air ports
are not obstructed. All this to avoid that the heater does not perform a
poor combustion and to avoid overheating which could cause damage to
the stove’s painted surfaces or a failed ignition of the flame. The amount
of ashes left over in the burner depends on the type of pellet used, even
the same type of fuel from different bags of a the same brand can have
different outcomes when burnt.
Emptying the ash drawer
The ash drawer is located inside the combustion
chamber. To access it, open the door, pull the drawer out
and then vacuum all ash deposits. This operation must be
done daily.
Cleaning the tube bundle
(see dedicated manual)
The cleaners can be accessed through the handle, that
must me moved according to the direction the arrows are
pointing, repeatedly at least four times. During the
operation you will notice a small amount of dust/ash falling from the top
of the combustion chamber. This operation must be performed weekly.
Cleaning the pellet tank
Monthly empty the pellet tank and vacuum all pellet dust residuals
deposited at the bottom.
FireWall
The combustion chamber is lined with Firewall.
This vermiculite based material developed by Moretti
Design allows to improve the quality of the combustion
due to its heat resistance, light weight and good insulation
capacity. The Firewall and the flame tend to become more clearer during
the combustion, when it is optimal. When the combustion is not optimal,
the Firewall tends to get dirty and assumes a more darker colour.
For the Firewall’s maintenance a brush should be used to dust the ashes
off. Do not use abrasive, wet or damp materials to clean the Firewall as
they may damage or weaken it. Do not use a vacuum cleaner. When
removing the Firewall, handle with care. If the stove has been running for
several hours, the Firewall might present slight abrasions on its surface,
this effect is quite normal because the combustion can create micro-
dents on the surface, anyway this doesn’t influence negatively the
integrity of the Firewall.
Cleaning the surfaces
Use a rag soaked with water for cleaning the painted metal surfaces.
The use of detergents or aggressive diluents can damage the stove’s
surfaces.