6
Residual risks
Certain parts of the stove, in particular the glass and flue, while in use
overheat and can cause burns, do not touch or handle unless with the
utmost care. The electrical parts can cause serious damage, do not
touch these parts without having disconnected the cable from the main
power supply.
SAFETY DEVICES
Breakage of the exhaust fan: If for any reason the fan breaks, a safety
measure intervenes and blocks the pellet flow (Er02), an alarm goes off
and stops the stove’s function.
Breakage of the auger motor: If the auger motor stops feeding pellet,
the system still continues to function on minimum levels then an alarm
goes off and the stove blocks (Er12, Er03).
Failed ignition: If there is a failed ignition, the stove goes into safe
mode and then into block (Er12). Unblock the stove and check if the
burner is clean and positioned properly before attempting another
ignition.
If the burner is not cleaned, the next ignition may cause a little
deflagration inside the combustion chamber. If this occurs, the
manufacturer will not accept any responsibility for damage to
persons, animals or things.
Electrical protection: The system is protected with a 4 A fuse that is
located on the back of the stove. To replace it, extract the tray next to the
switch only after disconnecting the power cable from the power supply,
replace the broken fuse and reinsert the tray, if the new fuse immediately
breaks, contact a technician.
Exhaust fume safety: If there are any anomalies with the smoke
expulsion from the system, an alarm will go off and the system will block
(Er02).
Pellet safety: If the temperature inside the pellet tank exceeds the
safety level, the system blocks (Er01). The reinstatement is automatic.
Power failure: If there is a short power failure in the power supply, the
system will go into block (Er15), if the lack of electricity is not brief, the
stove could release a small quantity of smoke in the room, if the air
intake has not been correctly connected to the outside. This is caused
by the scarce draw of the chimney flue and does not represent any
risk for one’s safety. When the power comes back, the system
switches itself off.
Warning: In the case the chimney catches fire, call the fire brigade.
MINIMUM SAFETY DISTANCES
Keep fuels and flammable substances at an adequate distance from the
stove. For minimum distances from flammable materials, one can refer
to the products identification plate located on the back of the stove.
Caution: For some models the minimum safety distance from
flammable materials may be different than those shown in the
figure below. Therefore, always refer to the product identification
plate generally located on the back of the stove to ensure minimum
safety distances for the specific model.
Note: If one wants to install the stove near a non-flammable wall, it is
possible to place it directly in contact with the wall, as long as it does not
obstruct any access to the electrical components or connections or
maintenance interventions.
FIRST IGNITION
Caution: The first ignition must be carried out by MORETTI DESIGN
qualified personnel that must also perform an overall check up of the
system.
All local and National laws and European standards must be met
when using the appliance.
Positioning the deflector
Before turning on the stove, it is necessary to insert the deflector inside
the combustion chamber (see dedicated manual).
Note: Once a month remove and clean the deflector. A failure to clean
can compromise the proper function of the stove.
Positioning the antenna
The position of the antenna, is very important in order to optimize the
transmission and reception of radio signals between the display radio
and stove itself for the management of the various functions.
Models with external antenna (metal sheet coated and Relax)
Make sure that the white tip of the antenna does not remain in contact
with any metal parts of the stove. Perform a signal quality test by using
the Radio Test function (page. 13) before switching the stove on. If the
signal is not optimal, remove the holding clip and unroll out the antenna
completely.
Models with internal antenna (glass or majolica coating)
Distance in mm

Other manuals for Moretti Design ARIA