EasyManua.ls Logo

Motorola ASTRO XTS 5000 I - Erasing a Key; Method 1 - Key Zeroization (Multikey Only)

Motorola ASTRO XTS 5000 I
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
Performance Checks
5
Introduction This section covers performance checks used to ensure that the radio meets
published specifications. The recommended test equipment listed in the
previous section approaches the accuracy of the manufacturing equipment,
with a few exceptions. Accuracy of the test equipment must be maintained in
compliance with the manufacturer’s recommended calibration schedule.
Checks should be performed if radio performance degradation is suspected.
Setup Supply voltage can be connected from the battery eliminator. The equipment
required for alignment procedures is connected as shown in Figure 4.
Figure 4. Radio Alignment Test Setup
Initial equipment control settings should be as indicated in Table 5 on
page 14, and should hold for all alignment procedures, except as noted.
BNC
COMPUTER
AUDIO GENERATOR
SINAD METER
AC VOLTMETER
TX
RX
30 dB PAD
30 dB PAD
RF GENERATOR
SYSTEM ANALYZER
OR COUNTER
WATTMETER
BATTERY
ELIMINATOR
REX-4424
TRANSMIT
RECEIVE
RADIO
PROGRAM/TEST CABLE
RKN4105_ OR RKN4106_
AUDIO IN
SET TO APPROX. 450mV FOR Tx
MEASURE 80mV FOR Tx
SMA-BNC
58-80348B33
TEST SET
RLN-4460_
RKN4105_ OR RKN4106_

Table of Contents