EasyManua.ls Logo

Motorola MVME162P-344SE - Serial Connections

Motorola MVME162P-344SE
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-28 Computer Group Literature Center Web Site
Hardware Preparation and Installation
1
Serial Connections
The MVME162P4 uses a Zilog Z85230 serial port controller to implement
the two serial communications interfaces. Each interface supports:
CTS, DCD, RTS, and DTR control signals
TXD and RXD transmit/receive data signals
TXC and RXC synchronous clock signals
The Z85230 supports synchronous (SDLC/HDLC) and asynchronous
protocols. The MVME162P4 hardware supports asynchronous serial baud
rates of 110b/s to 38.4Kb/s.
For additional information on the MVME162P4 serial communications
interface, refer to the Z85230 Serial Communications Controller Product
Brief listed under Manufacturer’s Documents in the Related
Documentation appendix. For additional information on the EIA-232-D
interface, refer to the EIA-232-D Standard.
The following figures illustrate the signal relationships and signal
connections in the various serial configurations available for ports A and
B.