1-10 Introduction: Specifications
Applicable
MIL-STD
810C 810D 810E 810F 810G
Methods Procedures Methods Procedures Methods Procedures Methods Procedures Methods Procedures
Low
Pressure
500.1 I 500.2 II 500.3 II 500.4 I/II 500.5 I/II
High
Temperature
501.1 I,II 501.2 I/AI,II/AI 501.3 I/A1, II/A1 501.4 I/HOT, II/
HOT
501.5 I/A1, II/A2
Low
Temperature
502.1 I 502.2 I/C3,II/C1 502.3 I/C3,II/C1 502.4 I/C3, II/C1 502.5 I/C3, II/C1
Temperature
Shock
503.1 I 503.2 I/AI,C3 503.3 I/A1, C3 503.4 I 503.5 I/C
Solar
Radiation
505.1 II 505.2 I 505.3 I 505.4 I 505.5 I/A1
Rain 506.1 I,II 506.2 I,II 506.3 I, II 506.4 I, III 506.5 I, III
Humidity 507.1 II 507.2 II 507.3 II 507.4 - 507.5 II/Agg
Salt fog 509.1 I 509.2 I 509.3 I 509.4 - 509.5 -
Dust 510.1 I 510.2 I 510.3 I 510.4 I 510.5 I
Vibration 514.2 VIII/F,W 514.3 I/I0,II/3 514.4 I/10, II/3 514.5 I/24 514.6 I/24
Shock 516.2 I,III,V 516.3 I,IV,VI 516.4 I, IV, VI 516.5 I, IV, VI 516.6 I, IV, VI
Environmental Specifications
*Operating Temperature -30 °C to +60 °C
Storage Temperature -40 °C to +85 °C
Thermal Shock Per MIL-STD
Humidity Per MIL-STD
ESD IEC 61000-4-2 Level 3
Dust and Water Intrusion IEC60529 - IP54
Packaging test Per MIL-STD
* Operating temperature specification for a Lilon battery is -10 °C to +60 °C.