3-2 Transceiver Performance Testing: Test Mode
3.3 Test Mode
3.3.1 Power Up Test Mode
3.3.1.1 Display Model
1. Press and hold the ON/OFF Button. Audible sound is heard when the radio is powering up.
2. The radio will display the following:
Figure 3-1. Power-Up Screen Icon
3.3.2 Front Panel AccessTest Mode
3.3.2.1 Display Model
1. To enter test mode, press the Side Programmable Button five times within 10 seconds after
the radio powers up.
2. The radio beeps once, when it enters test mode successfully.
3.3.3 RF Test Mode
3.3.3.1 Display Model
1. Upon entering RF Test Mode, the display shows RF for 2 seconds, and then shows the
default channel profile.
2. The default channel profile is CSQ, CH1, and 12.5 kHz.
→ For an example, C010 is for CSQ, CH1, and 12.5 kHz.
- First character indicates the Test Environment
- Second and third character indicates the Channel Index
- Fourth character indicates the Channel Spacing
Oscilloscope Source: Mod
Oscilloscope Horizontal: 10mSec/Div
Oscilloscope Vertical: 2.5kHz/Div
Oscilloscope Trigger: Auto
Monitor Image: Hi
Monitor Bandwidth: Narrow
Monitor Squelch: Middle setting
Monitor Vol: 1/4 setting
Current: 2.5 A
Table 3-1. Initial Equipment Control Settings
Service Monitor Power Supply Test Set