Beeps while primary source
is interrupted
Overload bypass:
When enabled, the unit will
transfer to line mode if
overload occurs in battery
mode.
Bulk charging voltage
(C.V voltage)
24V model default setting: 28.2V
If self-defined is selected in program 5, this program can be
set up. Setting range is from 24.0V to 29.2V for 24V model.
Increment of each click is 0.1V.
Floating charging voltage
24V model default to 27.0V
If self-defined is selected in program 5, this program can be
set up. Setting range is from 24.0V to 29.2V for 24V model.
Increment of each click is 0.1V.
24V model default setting: 21.0V
If self-defined is selected in program 5, this program can be
set up. Setting range is from 20.0V to 24.0V for 24V model.
Increment of each click is 0.1V. Low DC cut-off voltage will be
fixed to setting value no matter what percentage of load is
connected.
Battery equalization voltage
3KVA default setting: 29.2V
Setting range is from 25.0V to 30V for 3KVA model. Increment
of each click is 0.1V.
Setting range is from 5min to 900min.
Increment of each click is 5min.
Battery equalized timeout
Setting range is from 5min to 900
min. Increment of each click is 5 min.