Charger source priority:
To configure charger source
priority
If this inverter/charger is working in Line, Standby or Fault
mode, charger source can be programmed as below:
Solar energy will charge battery as
first priority.
Utility will charge battery only when
solar energy is not available.
Utility will charge battery as first
priority.
Solar energy will charge battery only
when utility power is not available.
Solar energy and utility will charge
battery at the same time.
Solar energy will be the only charger
source no matter utility is available or
not.
If this inverter/charger is working in Battery mode or Power
saving mode, only solar energy can charge battery. Solar
energy will charge battery if it's available and sufficient.
Auto return to default
display screen
Return to default
display screen
(default)
If selected, no matter how users
switch display screen, it will
automatically return to default display
screen (Input voltage /output
voltage) after no button is pressed for
1 minute.
If selected, the display screen will
stay at latest screen user finally
switches.