EasyManuals Logo

MSA 47K Series User Manual

MSA 47K Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
GB
DESCRIPTION MSA
10 Series 47K Gas Detector [SIL 2]
Operating temperature range PRP- sensor
Extended range *)
-25 °C to +55 °C
-40 °C to +55 °C
HT-PRP sensor -40 °C to +160 °C
Operating humidity range 5% to 95% RH non-condensing
Operating pressure range
800–1200 hPa
Air velocity Air velocity 0–6 m/s
[with duct mount flange: 0.5–20 m/s]
Poison resistance
PRP sensor and HT-PRP sensor:
10 ppm HMDS for 40 min.
[max. signal loss 5% of reading]
Dimension Ø 36 x 56 mm
Weight < 230 g
Material
St. St. 316
Accessory thread M36 x 1.5 mm
Sensor to junction box ¾” NPT or M25 x 1.5 mm
*) Extended range: The sensor extended temperature range is greater than the maximum specified in
EN 60079-29-1. It is therefore strongly recommended that if used above +55 °C or below -25 °C the
sensor is calibrated at the operating temperature.
**) The storage temperature range is also valid for spare parts and accessories