Series 47K Gas Detector [SIL 2] 19
5.3.1 47K-HT-PRP
Relative response factors of tested gases with reference to Propane.
These values are only valid for new sensors and, unless otherwise stated, refer to
an ambient temperature of 110 °C. In this case the displayed values may vary by
up to ±20% from the target gas concentration.
Sample gas 100% LEL
in vol%
Propane relative
response factor
Response
time [secs]
t
50
*)
Response
time [secs]
t
90
*)]
Methane 4.4 0.52 < 8 < 14
*) Response times are with a flow through adapter and a gas flow of 1 l/min
5.3.2 47K-PRP
Relative response factors of tested gases with reference to Propane.
These values are only valid for new sensors and, unless otherwise stated, refer to
an ambient temperature of 20 °C. In this case the displayed values may vary by
up to ±20% from the target gas concentration. Response times stated in the
enclosed table may vary by ±20% depending on the tolerances of individual
sensors.
Sample gas
100%
LEL
in vol%
Propane relative
response factor
Response
time [secs]
t
50
*)
Response
time [secs]
t
90
*)]
Propane
1,7 1.00
1)
14 24
Acetaldehyde
4 0.64 ²)
Acetic acid
3)
4 1.51 ²)
Acetic anhydride
3)
2 1.56 ²)
Acetone
2,5 0.94
1)
9 24
Acetylene
2,3 0.76 ²)
Acrylonitrile
2,8 0.75 ²)
Allyl alcohol
2,5 0.90 ²)
Ammonia
15 0.38 ²)
Benzene
1,2 1.21 ²)
1.3-Butadiene
1,4 1.01 ²)
i-Butane
1,3 1.20 ²)
n-Butane
1,4 1.09 ²)
1-Butylene
1,6 0.94 ²)
n-Butanol
(Butylalcohol)
1,4 1.40 ²)
2-Butanone
1,8 1.13
1)
12 31