63
Cleaning and Disinfecting the SCBA
G1 SCBA 2018 Edition
US
(2) Use the instructions on the label to prepare a solution of
Confidence Plus Germicidal Cleaner (P/N 10009971) in a
bucket or sink.
NOTE: The head harness can be cleaned as part of the
facepiece or removed to be cleaned separately.
(3) Submerge the facepiece in Confidence Plus Germicidal
Cleaner for a minimum of 30 seconds.
(4) Use a soft brush or sponge to clean the soiled facepiece.
(5) Rinse the facepiece and components thoroughly in clean
water that is not more than 110°F (43°C) and is preferably
running and draining.
(6) To clean and rinse the pressure-demand exhalation valve,
use a blunt object to push in on the stem and flush the
valve with clean water.
(7) Let the facepiece air-dry. Do not put parts near a heater or in direct sunlight to dry.
(8) Operate the exhalation valve manually to make sure it operates correctly.
(9) Make sure there is no water, moisture, or dampness on or in the facepiece before returning it to
service.
(10) Do a negative pressure seal test before returning the facepiece to service.