Safekeeping and Storage
G1 SCBA 2018 Edition
US
19 Safekeeping and Storage
WARNING!
Before putting the SCBA in storage, make sure the alkaline battery module has new batteries and/
or the rechargeable battery module is fully charged. Do NOT put the SCBA in storage without a
battery module (alkaline or rechargeable) installed.
Make sure the icon for a fully charged battery shows on the control module display and the low
battery alarm icon does NOT show on the HUD.
Do NOT drop the cylinder or hit the handwheel. An unsecured cylinder can become an airborne
projectile under its own pressure if the cylinder valve is opened even slightly.
Failure to obey these warnings can result in serious injury or death.
Make sure the central power battery (alkaline/rechargeable) is installed at all times, including when
the SCBA is out of service for storage or repair.
Do NOT put the SCBA or spare cylinders in storage within or near an area where the SCBA can or
might be exposed to any substances that will or might attack any part of the SCBA and prevent the
SCBA from operating as designed and approved.
Before putting the SCBA in a jump seat for storage, make sure there is no interference between the
SCBA and the jump seat. Make sure the SCBA and cylinder can be removed from the jump seat easily
without causing damage to the components.
Do NOT put the SCBA in storage with an empty or a partially filled cylinder. Always install a fully
charged cylinder so the SCBA is ready for use.
Do the procedures in Section 11 "Cleaning and Disinfecting the SCBA". Make sure the entire SCBA
is clean and dry.
Make sure the adjustment straps for the facepiece head harness are fully extended.
Put the complete SCBA in the storage case or a suitable storage location with easy access for emer-
gency use.
Store the rechargeable battery module fully charged at temperatures between -4°F – 104°F
(-20°C 40°C).
MSA recommends charging the rechargeable battery module every 6 months if it has not been in use
or kept continuously in a charging station.
19.1 Facepiece
WARNING!
To prevent damage to the facepiece, do NOT keep loose objects in the facepiece container.
Failure to obey this warning can result in serious injury or death.
Use a pouch or container to keep the facepiece safe.
MSA rubber products are protected by an anti-aging agent that can become visible as a light coating.
This coating is harmless and can be removed during cleaning.
To extend the life of rubber components, keep them in a cool, dry place that is protected from ultravi-
olet radiation, according to ISO 2230, Rubber Products – Guidelines for Storage.